MASSA PRODUCTS CORPORATION June 11, 2013
Product Manual 15 M3 Wireless Ultrasonic Level Sensor
9.2.3 Awake Timer Register (addr = 6-7)
The Awake Timer register contains the time value the XBee radio will remain awake after the Deep-Sleep timer has expired.
Minimum time for this register is 6 (12 seconds). Incoming messages to the sensor will reset this timer extending this awake
period and allows long messaging such as waveform retrieval to be passed before the sensor goes back to sleep. The resolution
for this 2-byte register is 2 seconds with the LSB at location 6 and the MSB at location 7. This function will be ignored if the
Deep-Sleep Timer is set to zero and the sensor will operate in the Manual mode as described below. If the Awake Timer is
programmed to be longer than the Deep-Sleep Timer, a fault will be indicated in the Status1 byte message and bit 0 will be set in
the Error Indicator Register (section 9.2.7). On error, both of the Deep-Sleep and Wake Up timer registers will be replaced with
the default values (see Section 9.1).
9.2.4 Outgoing Message Mode Register (addr = 8)
The Outgoing Message Mode register contains the value on the method the sensor will send Outgoing Messages when it wakes up
from Deep-Sleep. The table below indicates the operating mode based on this register value. This function will be active when
the Deep-Sleep register (4-5) is non-zero. If the application expects the gateway to drop the sensor from its device table, it is
recommended Auto Send 2 messaging be used with a minimum value for the Awake Timer set to 12 (24 seconds). The gateway
may not receive the 1
st
sensor message as it is attempting to associate itself with the gateway, but the 2
nd
copy should be received.
See section 8.2.1.2 for the outgoing message format. See section 9.2.10 for limiting the # of Event Blocks within the message.
Reg Value Message Mode Operation after waking up from Deep-Sleep
0 Manual Sensor will only send messages upon request during the Awake period (default setting).
1 Auto Send 1 Sensor will send a single Command 1 message containing up to 8 blocks of recorded Event Data
and will wait for the entire programmed Awake Time for any normal protocol requests. There is
no demand for any acknowledgement and no retry will be sent.
2 Auto Send 2 Sensor will send a single Command 1 message containing up to 8 blocks of recorded Event Data
and will wait for ½ the programmed Awake Time then sensor will send a second copy. Awake
Time will continue in its entirety for any normal protocol requests. There is no demand for any
acknowledgement and no retry will be sent.
3 Auto Send 3 Sensor will send a single Command 1 message containing up to 8 blocks of recorded Event Data
and will wait for ½ the programmed Awake Time for a protocol acknowledgement (Command
200). If acknowledge message is not received within ½ of Wake up Time, then a second copy will
be sent. Awake Time will continue in its entirety for any normal protocol requests.
4 Acknowledge Sensor will send a single Acknowledge message indicating that it is awake. Coordinator now can
send messages during the awake period.
5 Auto Send 5 Sensor will first acquire range and other status information followed by sending a single Command
1 message containing up to 8 blocks of recorded Event Data. The Awake Time will continue in its
entirety for any normal protocol requests. There is no demand for any acknowledgement and no
retry will be sent. The Data Collection Interval Register is disabled. (FW ver 26 or greater)
6 Auto Send 6 Sensor will first acquire range and other status information followed by sending a single Command
1 message containing up to 8 blocks of recorded Event Data. Sensor will wait for ½ the
programmed Awake Time then send a second copy. The Awake Time will continue in its entirety
for any normal protocol requests. There is no demand for any acknowledgement and no retry will
be sent. The Data Collection Interval Register is disabled. (FW ver 26 or greater)
This is the Acknowledge Message sent by Coordinator after it has received Event Data and Configuration Register 8 set to 3.
<Destination ID> <Sender ID> <Message Length> <Command> <AcknowledgeToCommand> <Checksum>
Sensor ID Host ID 6 200 1 checksum
default=1 default=251 Acknowledge read history buffer
This is the Acknowledge Message sent by Sensor after sensor wakes up and Configuration Register 8 set to 4.
<Destination ID> <Sender ID> <Message Length> <Command> <AcknowledgeToCommand> <Checksum>
Host ID Sensor ID 6 200 0 checksum
default=251 default=1 Acknowledge
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 28 29

Comentarios a estos manuales

Sin comentarios